RANEWARE OPERATORS MANUAL ECS v2
ENGINEERED CONFERENCE SYSTEMS
Contents
INSTALLING RANEWARE ......................................... 2
ABOUT ECS RANEWARE ......................................... 4
APPLICATIONS & USING PRESETS ...................13
SITE SURVEY & SYSTEM CHECKLIST............... 20
ECS ALIGNMENT PROCEDURE ...........................21
TROUBLESHOOTING ...............................................23
ECB 62 DEVICE CONTROL LANGUAGE .............24
ECS RaneWare Manual
This manual contains information on RaneWare soft-
ware installation and ECS controls, device control language,
system setup, applications and operation.
All software controls are printed here in sans-serif type
to help distinguish between hardware and software.
ECS consists of software-driven hardware. Consult the
ECS Hardware Manual for the ECB 62 Base and ECM 82
Mixer installation options, audio and data connections,
control and indicator descriptions, and audio specifications.
This manual first begins with RaneWare installation,
then describes all software controls, and those particular to
ECS. Applications & Using Presets describes example
systems that may be used as a starting point for your own
customized application. A Checkist and Site Survey
addresses questions that may arise during installation or
operation. After the system is connected and installed in
place, the Alignment Procedure may begin. For those using
control systems such as AMX or Crestron, the Device
Control Language is provided.
Overview
ECS is hardware controlled by software. RaneWare®
is the software, and the family of products that the
software controls. RW 232™ describes the protocol and
the DB-9 hardware used to communicate between units.
The ECB 62 Base is controlled through the RW 232
serial bus. This interface operates on any RS-232 serial
port, allowing control system communication with up to
16 RW 232 products at a time, each with a unique
address. The ECM 82 Mixers are controlled through the
Base using a proprietary Expansion Interface cable. Rane
RW 232 products can be controlled from remote locations
with the optional RPD 1 Programming & Diagnostics
Unit (see the RPD 1 data sheet).
ECS is covered by US Patent 5,848,146
RaneWare is a registered trademark of Rane Corporation
Windows is a registered trademark of Microsoft Corporation
Przeglądanie stron 0
1 2 3 4 5 6 ... 32 33

Podsumowanie treści

Strona 1 - Overview

RW Manual-1RANEWARE OPERATORS MANUAL ECS v2ENGINEERED CONFERENCE SYSTEMSContentsINSTALLING RANEWARE ... 2ABOUT E

Strona 2 - INSTALLING RANEWARE

RW Manual-10System tabNoise SourceWhen checked, inserts a pink Noise Source at any ECB 62right channel Output that is on. This is useful during system

Strona 3 - Device Selection

RW Manual-11Near Signal Offset signal flowNoise Gate activation and levelThis feature is useful in multipoint conferencing when youwant the near end’s

Strona 4 - ECS RANEWARE

RW Manual-12to reply “yes,” or to cough, or shuffle papers. This avoids theproblem of the camera switching over to someone who isblowing their schnoz.

Strona 5 - RW Manual-5

RW Manual-13In this application, Port Inputs must be Selected by theRoom Controller. The laptop is only used for the initialsystem setup. It is then r

Strona 6 - RW Manual-6

RW Manual-14 This block diagram illustrates the Applications - System 1 example on the preceding page.

Strona 7 - RW Manual-7

RW Manual-15This unit-to-unit wiring diagram illustrates the Applications - System 1 example on the preceding pages.

Strona 8 - RW Manual-8

RW Manual-16RaneWare Folders forAPI.ECS Memory 2

Strona 9 - RW Manual-9

RW Manual-17System 2: Boardroom with Program StereoThe following illustrates an ECS with 16 mics, stereo program speakers, mono ceilingspeakers, a dig

Strona 10 - System tab

RW Manual-18System 3: Distance LearningThis illustrates a distance learning application usingbroadband video that requires reinforcement of the teache

Strona 11 - RW Manual-11

RW Manual-19System 4: Large Conference CenterMemory 2 - Selecting this Preset Memory connects theConference Room (Port 1) to the Codec (Port 2).Memory

Strona 12 - RW Manual-12

RW Manual-2Starting RaneWareOnce RaneWare is installed, a RaneWare program groupis created. When the software is first installed, Rane’sSoftware Licen

Strona 13 - Conference Room

RW Manual-20SITE SURVEYFor ECS to operate properly the following must be closelyobserved:Ambient Noise Level - Air conditioning equipment (listenfor r

Strona 14 - RW Manual-14

RW Manual-21QUICK OVERVIEWa. Set up the ECM 82 Mic levels.b. Set up the Input levels to the ECB 62.c. Set the Mic operation for each Input on the ECM

Strona 15 - RW Manual-15

RW Manual-22MIC THRESHOLD LEVEL SETUPOnce all Mics have been adjusted, the Threshold Levelsneed to be set. In most applications operating the Mics wit

Strona 16 - RW Manual-16

RW Manual-23TROUBLESHOOTINGPOWER LED is Off:Check POWER connection on rear panel, and that theremote supply is connected to a live AC source.No commun

Strona 17 - RW Manual-17

RW Manual-24Definition: Two’s Complement: The result ob-tained when all the data bits are invertedand 1 is added to the result. Used torepresent negat

Strona 18 - System 3: Distance Learning

RW Manual-25Index Hex Mixer 1 Parameters:66 $42 Echo Canceller Bypass (ON/OFF)* 1/0 (byte) 1 = ON, 0 = OFF67 $43 Echo Canceller 3 kHz (ON/OFF)* 1/0 (b

Strona 19 - RW Manual-19

RW Manual-26372-378 Mic 37 Parameters Same as Mic 1 Parameters379-385 Mic 38 Parameters Same as Mic 1 Parameters386-392 Mic 39 Parameters Same as Mic

Strona 20 - SYSTEM CHECKLIST

RW Manual-27Memory number codes (MEMNUM):$00 = live or working memory, $01 = preset memory #1, $02 = preset memory #2, ... , $10 = preset memory #16 (

Strona 21 - ECS ALIGNMENT PROCEDURE

RW Manual-28Lock device (85 hex):Transmit ADDR header ($FB xx FB xx, where xx = ADDR)Get DTGet IDTransmit $00 $02 (where $00 02 = number of data bytes

Strona 22 - RW Manual-22

RW Manual-29SNPL Stored Name Parameter List (SNPL):Index Hex Parameters Encoding Method00-08 $00-$08 Output Name 1 8 (char)09-16 $09-$10 Outpu

Strona 23 - TROUBLESHOOTING

RW Manual-3Memory & SecurityECS can be operated on a daily basis through a computerif a system controller is not installed. To preserve memorysecu

Strona 24 - Data Structures:

RW Manual-30Get data from channel (01 hex):Transmit ADDR header ($FB xx FB xx, where xx = ADDR)Get DTGet IDTransmit $00 $08 (where $00 08 = number of

Strona 25 - RW Manual-25

RW Manual-31Get Expansion Revisions (0A hex):Transmit ADDR header ($FB xx FB xx, where xx = ADDR)Get DTGet IDTransmit $00 $02 (where $00 02 = number o

Strona 26 - ECB 62 Global Parameters

RW Manual-32Notes1. When the value $FB occurs anywhere except in an ADDR header, it is repeated.2. The data size is the number of bytes, prior to the

Strona 27 - RW 232 Commands

RW Manual-33Example Packet Expansion code for RW 232 Messages// 09-10-96 - Devin Cook (Derived from RW232.CPP code)//-----------------------------

Strona 28 - RW Manual-28

RW Manual-4ECS RANEWAREThere are 4 sections to the ECS controlling software:Status (top screen section)Port (1st tab)Mixer (2nd tab)System (3rd tab)Wh

Strona 29 - RW Manual-29

RW Manual-5Port PagePortThe Port tab allows configuration of the six individualECB 62 Ports. Status signals of a Port have no affect on Portaudio—this

Strona 30 - RW Manual-30

RW Manual-6Off: Audio on this Port will not trigger the Port Signalindicator on, nor will the Port be able to become the Master.See also: Status Indic

Strona 31 - RW Manual-31

RW Manual-7MixerMixerThis selects one of six ECM 82 Mixers.Output buttonThis toggles the ECM 82’s Mix Out between on (greenindicator, depressed button

Strona 32 - RW Manual-32

RW Manual-8maintain the gain before feedback margin of a system. ThisNOM operation avoids the feedback that can occur as moreand more mics are gated o

Strona 33 - RW Manual-33

RW Manual-9Gate ModeUnique among automatic mic mixers, in ECS each Miccan be independently set to Last On or Gated. A Micassigned as Gated simply open

Komentarze do niniejszej Instrukcji